Abstract
Phenolic compounds are pollutants which have high toxicity and could be harmful to the environment even at low concentrations. The degradation of phenolic has been conducted by various methods including photocatalytic and ozonation. However, these methods require high costs and large energy. Therefore, plasma electrolysis by the Fenton reaction may be an alternative method for phenol degradation. The purpose of this study is to determine the optimum conditions for phenol degradation by adding Fe2+ ions. The result shows that the most effective phenol degradation was obtained by using an optimum power of 700 watts with an air injection flow rate of 0.2 L/min and addition Fe2+ 20 ppm ions for 30 min experiments. Based on these conditions, the concentration of phenol in waste was reduced to 0.425 mg/L and the highest percentage of phenol degradation (99.58%) was observed. The final phenol concentrations obtained in this study met the quality standards for clean water at a concentration of 1 mg/L as well as the quality standards for drinking water treatment at a concentration of 0.5 mg/L.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.