Abstract

The flow field inside a 50 percent eccentric whirling annular seal operating at a Reynolds number of 24,000 and a Taylor number of 6600 has been measured using a three-dimensional laser-Doppler anemometer system. Flush mount pressure and wall shear stress probes have been used to measure the stresses (normal and shear) along the length of the stator. The rotor was mounted eccentrically on the shaft so that the rotor orbit was circular and rotated at the same speed as the shaft (a whirl ratio of 1.0). This paper presents mean pressure, mean wall shear stress magnitude, and mean wall shear stress direction distributions along the length of the seal. Phase-averaged wall pressure and wall shear stress are presented along with phase-averaged mean velocity and turbulence kinetic energy distributions located 0.16c from the stator wall, where c is the seal clearance. The relationships between the velocity, turbulence, wall pressure, and wall shear stress are very complex and do not follow simple bulk flow predictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.