Abstract

In this study, electrical measurements on ferroelectric random-access memory by prior x-ray irradiation are conducted. Compared with an unirradiated device, parameters such as current leakage and remnant polarization of the irradiated device were unexpectedly improved. Besides, better reliabilities including the number of endurance times and retention time have also been demonstrated. To clarify the underlying physical mechanism, the electrical properties are analyzed. The current–voltage curve (I–V) implies a change in the grain size in the ferroelectric layer (FL), and the capacitance–voltage curve (C–V) profile indicates that the FL undergoes a phase change during irradiation. Finally, according to the electrical results, a physical model is proposed as an explanation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.