Abstract
Step and sinusoidal forcings were delivered to the wrists of 10 patients with advanced essential tremor using a computer-controlled torque motor. Consistent (type 0) phase resetting was produced in only 5 patients, whereas all 10 patients exhibited harmonic and 2: 1 subharmonic entrainment of essential tremor. These results indicate that the oscillator of essential tremor is coupled to the stretch-reflex arc. Irregularity in the tremor rhythm and postperturbation mechanical-reflex oscillations obscured the phase of essential tremor, thereby impeding the computation of phase resetting curves. Sinusoidal forcings circumvented these problems, but frequency entrainment was produced only by forcings at frequencies within ±1 Hz of the tremor frequency and its second harmonic. Resonance accompanied frequency entrainment and probably plays a role in the clinical expression of tremor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.