Abstract
Magnetic flux leakage (MFL) based on phase extraction for detecting the subsurface defects in ferromagnetic steel plate was investigated. The relationship between electromagnetic field phase and the subsurface defect was analyzed. Low-frequency alternating current (AC) excitation source and high-power magnetizer arrangement with Hall sensor were used to increase the skin depth of the MFL. Experiments results showed that 12 mm deep subsurface defect can be detected by using the phase extraction means, which is about two times higher than that by using the amplitude method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.