Abstract

The information of three-phase currents are very important for motor control. Some three-phase current reconstruction techniques were used in conventional two-level inverters using single DC current sensor for the purpose of cost reduction and sensor fault-tolerance. However, the validity would be affected because of planar bus bar and capacitor. A DC-link current sensor measures the sum of capacitor current and phase current. In this paper, a mathematical model is built and the parameters are recognized when the system is running. If the phase current sensor failure occurs, the state observer will be used to calculate the phase current.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.