Abstract

The control of gain and phase delay in a cyclotron-resonance maser (CRM) amplifier is essential for a variety of applications. In this experiment, the gain and phase-delay variations are measured with respect to controlling parameters; the electron-beam current and the axial magnetic field. Following Chu et al. [Phys. Rev. Lett. 74, 1103 (1995)], the CRM amplifier comprises of a distributed-loss waveguide to enable high gain without oscillations. Our experiment yields an amplification up to 26 dB, and a phase-delay control range of 360 degrees. In order to keep a fixed gain with the varying phase delay, the two controlling parameters (i.e., the solenoid field and the beam current) are operated together in a compensating mode. The experiment is conducted in a frequency of 7.3 GHz, with an electron beam of 18-kV voltage and 0.25-0.4-A current. The experimental results are compared with a theoretical model. Practical implementations of gain and phase control in CRM devices are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.