Abstract
This paper reports the validation of an assay for obtusifolin based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and its application to a preclinical pharmacokinetic study in rats. After sample preparation of plasma and tissue homogenates by protein precipitation, the analyte and internal standard (IS) were separated by a reversed-phase chromatographic system in a run time of 5.0 min and detected by negative ion electrospray ionization followed by selected reaction monitoring of the precursor-to-product ion transitions at m/z 283.0-268.1 for obtusifolin and m/z 329.0-314.1 for IS. The assay was linear in the concentration range 1.0-500 ng/ml with the LLOQ of 1.0 ng/ml. In the pharmacokinetic study of an intragastric administration of 1.3 mg/kg obtusifolin, the maximum plasma concentration of obtusifolin was 152.5 ± 62.3 ng/ml, reached at 0.39 ± 0.17 h. The AUC0-t and AUC0-∞ were 491.8 ± 256.7 and 501.7 ± 256.7 ng × h/ml, respectively, with an elimination half-life of 3.1 ± 0.7 h. Obtusifolin was rapidly distributed into tissues, with the highest distribution in the liver and less in the brain. These results will give some insights for further pharmacological investigation of obtusifolin.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.