Abstract

BackgroundEzetimibe is a new class of antihyperlipidemic agent indicated for the prevention of atherosclerosis disease and for the treatment of hypercholesterolemia. Information on the pharmacokinetic profiles of ezetimibe tablet in healthy Chinese volunteers are lacking, and regulatory requirements necessitate a bioequivalence study of ezetimibe tablet versus Ezetrol® in China.MethodsA single-dose randomized, open-label, two-group, two-period crossover study was conducted in 59 healthy Chinese volunteers under fasting or fed conditions to assess the bioequivalence between two preparations. Eligible participants were randomly divided into fasted and fed groups. Blood samples were collected at specified time intervals, and the plasma concentrations of ezetimibe and ezetimibe glucuronide were determined by a validated liquid chromatography-tandem mass spectrometry (LC–MS/MS) method. PK and bioavailability parameters were estimated via non-compartmental methods. Adverse events were also recorded.ResultsFifty-nine healthy volunteers were enrolled in the study. The main pharmacokinetic parameters of total ezetimibe in the plasma of the ezetimibe tablet (10 mg) and the Ezetrol® (10 mg) after a single fasting administration: Cmax were (65.73 ± 47.14), (71.32 ± 51.98) ng·mL− 1; Tmax were 1.75, 1.25 h; T½ were (17.09 ± 13.22), (17.35 ± 12.14) h; AUC0-t were (643.34 ± 400.77), (668.49 ± 439.57) h·ng·mL− 1; AUC0-∞ were (706.36 ± 410.92), (734.23 ± 468.26) h·ng·mL− 1. The main pharmacokinetic parameters of total ezetimibe in plasma of ezetimibe tablet (10 mg) and Ezetrol® (10 mg) after a fed administration: Cmax were (83.38 ± 38.95), (84.74 ± 34.62) ng·mL− 1; Tmax were 2.50, 2.50 h; T½ were (22.56 ± 12.68), (19.80 ± 15.59) h; AUC0-t were (494.21 ± 208.65), (536.69 ± 209.11) h·ng·mL− 1; AUC0-∞ were (573.74 ± 252.74), (604.75 ± 247.13) h·ng·mL− 1. The main pharmacokinetic parameters Cmax, AUC0-t, and AUC0-∞ of the two drugs were analyzed by variance analysis after logarithmic transformation. The total ezetimibe under fasting state with 90% confidence intervals (CIs) were 85.29 ~ 97.19, 90.41% ~ 104.38%, and 90.81 ~ 106.05%; total ezetimibe in fed state were 86.36% ~ 109.17, 84.96% ~ 96.40, and 85.32% ~ 101.0%. The 90% CIs of the ratio of geometric means (GMRs) of Cmax, AUC0-t, and AUC0-∞ of Ezetrol® and ezetimibe tablet both fasting and fed conditions fell within the conventional bioequivalence criteria of 0.80–1.25. Both Cmax and AUC met the predetermined criteria for assuming bioequivalence. No severe adverse events were observed.ConclusionsThe test ezetimibe tablet and Ezetrol® were determined to be bioequivalent under both fasting and fed conditions in Chinese people.Trial registrationClinicaltrials, NCT05681247 (retrospectively registered in 11/01/ 2023).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call