Abstract
BackgroundThe standard anticoagulation therapy for patients implanted with left ventricular assist devices (LVADs) includes warfarin therapy. We developed a cloud-based home medical management information-sharing system named as LVAD@home. The LVAD@home system is an application designed to be used on iPad tablet computers. This system enables the sharing of daily information between a patient and care providers in real time. In this study, we reported cases of outpatients with LVADs using this system to manage anticoagulation therapy.Case presentationThe patient, a man in his 40s with end-stage heart failure owing to non-ischemic dilated cardiomyopathy, underwent LVAD implantation and warfarin was started on postoperative day 1. He started to use LVAD@home to manage warfarin therapy after discharge (postoperative day 47). He sent his data to care providers daily. By using this system, the pharmacist observed his signs of reduced dietary intake 179 days after discharge, and after consulting the physician, told the patient to change the timing of the next measurement earlier than usual. On the next day, the prothrombin time-international normalized ratio increased from 2.0 to 3.0, and thus the dose was decreased by 0.5 mg. Four patients used this system to monitor warfarin therapy from October 2015 to March 2018. In these patients, the time in therapeutic range was 90.1 ± 1.3, which was higher than that observed in previous studies. Additionally, there were no thromboembolic events or bleeding events.ConclusionsThe cloud-based home management system can be applied to share real-time patient information of factors, including dietary intake that interact with warfarin. It can help to improve long-term anticoagulation outcomes in patients implanted with LVAD.
Highlights
The standard anticoagulation therapy for patients implanted with left ventricular assist devices (LVADs) includes warfarin therapy
Anticoagulation therapy with warfarin requires precise dose adjustments based on the periodic monitoring of prothrombin time-international normalized ratio (PT-INR) to minimize the risk of bleeding
The LVAD@home system, an application designed to be used on iPad tablet computers, enables data on multiple factors, such as warfarin dose, selfchecked PT-INR, blood pressure, dietary intake, body condition, body temperature, body weight, urine color, and other physical conditions, to be recorded and shared daily between patients and care providers in real time
Summary
The cloud-based home management system can be applied to share real-time patient information of factors, including dietary intake that interact with warfarin.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Pharmaceutical Health Care and Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.