Abstract

Particle profiles such as the average diameter, size distribution and dispersion, as well as the zeta potential, of commercially available intravenous fat emulsions of high-calorie nutrient fluids (6 products) and drug carriers (4 products) were examined using photon correlation spectroscopy (dynamic light scattering). Wide variations were observed in number-weighted (dn), weight-weighted (dw) and z-average diameters, and dw/dn ratios as a measure of polydispersity. Average size is not sufficient for the pharmaceutical characterization of particles and the determination of size distribution or dw/dn value is essential for more precise information. Although measuring the zeta potential of fat emulsions is of considerable value in estimating their stability on long-term storage, a medium which accurately reflects the environment of the droplets in the system of interest should be chosen when diluting the emulsion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.