Laboratory spray tests have been used to evaluate the protection offered by two distinct nonwoven fabrics with and without fluorocarbon finishes. The fabrics were contaminated with dicofol field spray mix at coverage levels ranging from 50 to 200 mg/m 2, values typical of actual field exposures of pesticide spray applicators. Half the samples were subjected to an external compression pressure of 1 psi immediately after contamination (pressure penetration test). The remaining fabrics were allowed to dry without manipulation (capillary penetration test). Increasing contamination level and application of an external mechanical pressure greatly increased the pene tration of dicofol through all test fabrics. All four test fabrics provided protection against capillary penetration, usually at levels greater than 99%. In pressure penetration testing, the performance of the two unfinished fabrics was significantly better than that of the finished fabrics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.