Abstract

Stress Corrosion Craking (SCC) generally attack to metals (steel) under internal stress. Fastener could arised internal stress to material that fastened, such as plat or other material. The experiment to observed SCC could used C-Ring method as standard ASTM G38-01(2007). Fastener and base material that made C-ring corroded in sea water with various stresses that was arrised by fastener. The result of research showed that hardness of spesimen (fastener and C-ring) was increase with increase in stress, the hardness indicated there were internal stress in spesimen. Corrosion rate for spesimen was increase with increase in stress, the higher corrosion rate at spesimen of C-ring for arrised stress 256 kg was 24,20 MPY. and lower arrised stress 69 kg was 19,14 MPY. The spesimen of fastener for arrised stress 256 kg was 7,97 MPY. and lower arrised stress 69 kg was 6,89 MPY. Duration experiment time were 9 day.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.