Abstract

Background: Transcatheter edge-to-edge tricuspid valve repair (T-TEER) for tricuspid regurgitation (TR) is always guided by transesophageal echocardiography (TEE). As each patient has unique anatomy and acoustic window, adding transthoracic echocardiography (TTE) and cardiac CT could improve procedural planning and guidance. Objectives: We aimed to assess T-TEER success and outcomes of a personalized guidance approach, based on multimodality imaging (MMI) of patient-tailored four right-sided chamber views (four-right-ch), as depicted by CT, TTE, TEE and fluoroscopy. Methods: Patients were assigned to MMI or classical TEE guidance, depending on TTE acoustic window. In MMI patients, planning included cardiac CT, which determined the fluoroscopic angulations of the specific four-right-ch, while guidance relied heavily on TTE, with minimal intermittent TEE for leaflet grasping and result confirmation. Both TTE and TEE were matched to respective CT and fluoroscopy four-right-ch. TR severity and quality of life (QoL) parameters were assessed from baseline to 12 months. Results: A total of 40 T-TEER patients were included, with 17 procedures guided by MMI and 23 solely by TEE. Baseline characteristics were similar between groups, e.g., age (83.1 ± 4.1 vs. 81 ± 5.3, p = 0.182) or STS-Score (11.1 ± 7.4% vs. 10.6 ± 5.9%, p = 0.813). The primary efficacy endpoint of ≥one-grade TR reduction at 30 days was 94% (16/17) in MMI vs. 91% (21/23) in TEE patients, with two or more TR grade reduction in 65% vs. 52% (p = 0.793). Device success was overall 100%, with no device-related complications, but three TEE-associated cases of gastrointestinal bleeding in the TEE-only group. By 12 months, all 15 MMI and 19 TEE survivors improved NYHA functional class and QoL, e.g., Kansas City Cardiomyopathy Questionnaire Score Δ29.6 ± 6.7 vs. 21.9 ± 5.8 (p = 0.441) pts., 6-min walk distance Δ101.5 ± 36.4 vs. 85.7 ± 32.1 (p = 0.541) meters. Conclusions: In a subset of patients with good TTE acoustic window, MMI guidance of T-TEER is effective and seems to avoid gastroesophageal injuries caused by TEE probe manipulation. TR reduction, irrespective of guidance method, impacts long-term QoL.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.