The present work seeks to calculate and development of a new set of the personal dose equivalent conversion coefficients (Skins Dose) for mono-energetic photons (in absorbed dose and Kerma approximations), electrons and positrons from 10 keV to 10 MeV on the phantom ICRU tissue. The conversion coefficients calculations were two ways: Monte Carlo and development an analytical approach using FORTRAN program. The results obtained in this work were found to be in good agreement with to those published in joint report of ICRU and ICRP, 2017 [1]. The numerical comparison was made to validate DOSRZnrc code for conversion coefficients calculations as well as testing the developed of an analytical a new approach using FORTRAN. Our study can be useful to improve standards of protection for medical workers for procedure resulting in potentially high exposures and to develop methodologies for the best assessing and for reducing exposures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.