Abstract
This paper reports the frequency response measurements and equivalent circuit modelling of a piezoelectric ultrasonic atomizer device. It aims to examine the perpetual-operation performance of piezoelectric ultrasonic transducers in atomization applications. The resonance frequency of a water-loaded atomizer device is found to remain virtually unchanged in perpetual operation of less than 100 hours. An equivalent circuit model is developed based on the measurement data and it reveals that the characteristic parameters in the model changes over time. In particular, the change in the mechanical-equivalent resistance R m in the model and the resonance frequency drift are discussed for the driving circuit design in atomizer system development.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.