Abstract

A requirement exists to permanently mark medical instruments and implants. These materials are selected for the specific applications by mechanical properties and resistance to corrosion and aggressive cleaning methods. The major challenge presented for laser marking is to create a visible mark without compromising the corrosion resistance of the material. This requires that the surface of the material does not become molten, and that the mark is produced by building up an oxide layer that becomes visible and enriched with chromium to maintain corrosion resistant properties. The paper examines the marking conditions required for corrosion resistant marking, in line with ASTM F1089-02, of stainless steels including 304, 17-4 and 17-7 using a 1070nm fiber laser marker. The effect of parameters such as peak power density, pulse frequency, pulse shape, fill overlap and marking speed on the level of corrosion resistance are presented. In addition to the experimental data, a moving point source thermal model is presented to provide a more in depth understanding of the heat input during the laser marking process, and gain further insight into the thermal control necessary during the oxide growth process to enable corrosion resistant marks.A requirement exists to permanently mark medical instruments and implants. These materials are selected for the specific applications by mechanical properties and resistance to corrosion and aggressive cleaning methods. The major challenge presented for laser marking is to create a visible mark without compromising the corrosion resistance of the material. This requires that the surface of the material does not become molten, and that the mark is produced by building up an oxide layer that becomes visible and enriched with chromium to maintain corrosion resistant properties. The paper examines the marking conditions required for corrosion resistant marking, in line with ASTM F1089-02, of stainless steels including 304, 17-4 and 17-7 using a 1070nm fiber laser marker. The effect of parameters such as peak power density, pulse frequency, pulse shape, fill overlap and marking speed on the level of corrosion resistance are presented. In addition to the experimental data, a moving point source thermal model is...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.