Abstract

Tibiotalocalcaneal arthrodesis using intramedullary nail fixation is a technically demanding procedure. Periprosthetic fracture in association with tibiotalocalcaneal arthrodesis is a rare occurrence, with relatively few instances reported. The present report describes 2 such instances that occurred after tibiotalocalcaneal arthrodesis using retrograde femoral intramedullary nail fixation. Studies have suggested that a longer nail might decrease the incidence of periprosthetic fracture. Other factors could also have an influence, including the proximal screw orientation and the presence of medical comorbidities, such as osteopenia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.