Abstract

In our institution, between January 2010 and December 2017, 15 140 peripherally inserted central catheters (PICCs) were inserted in 12 314 patients. Using time-series analysis to evaluate the annual historical trend (AHT), we observed a significant increase in bloodstream infections (BSIs; AHT = 24; p < 0.001) and associated deaths (AHT = 3; p 0.02) in patient with PICCs. The risk of experiencing a BSI was significantly higher in patients with PICCs (odds ratio = 9.6; 95% confidence interval, 9.08–10.18; p < 0.001). To reduce PICC-related BSIs and their related mortality, it is important to limit the overuse of PICCs and to implement a ‘no PICC’ policy by limiting the insertion of PICCs to situations without other available options.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.