Abstract
It is desirable to minimize peripheral thermal damage during laser irradiation, since thermal damage to collagen and mineral compromises the bond strength to restorative materials in dentin and inhibits healing and osteointegration in bone. There were two primary objectives of this study. The first objective was to measure the degree of thermal damage peripheral to incisions in dentin produced with lasers resonant to the specific absorption bands of water, collagen, and hydroxyapatite with varying pulse duration using polarized-light microscopy (PLM). The second objective was to use synchrotron radiation infrared spectromicroscopy (SR-FTIR) to identify the specific chemical nature of the optical changes observed under PLM in the respective zones of thermal damage peripheral to the laser incisions. Precise incisions were produced in 3 x 3 mm2 blocks of human dentin using CO2 (9.6 microm), Er:YSGG (2.79 microm), and Nd:YAG (355 nm) lasers with and without a computer controlled water-spray. Optical coherence tomography (OCT) was used to obtain optical cross-sections of each incision to determine the rate of ablation. The peripheral thermal damage zone around each incision was analyzed using PLM and SR-FTIR. Thermally induced chemical changes to both mineral and the collagen matrix were observed with SR-FTIR with a 10 microm spatial resolution and those changes were correlated with optical changes observed with PLM. Minimal (<10 microm) thermal damage was observed for pulse durations less than the thermal relaxation time (Tr) of the deposited laser energy, with and without applied water at 9.6 microm and with only applied water at 2.79 microm. For pulse durations greater than Tr, greater peripheral thermal damage was observed for both IR laser wavelengths with and without the water-spray. There was minimal thermal damage for 355 nm laser pulses less than Tr with and without applied water; however, extensive mechanical damage (cracks) was observed. High resolution SR-FTIR is well suited for characterization of the chemical changes that occur due to thermal damage peripheral to laser incisions in proteinaceous hard tissues. Sub-microsecond pulsed IR lasers resonant with water and mineral absorption bands ablate dentin efficiently with minimal thermal damage. Similar laser parameters are expected to apply to the ablation of alveolar bone.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.