Abstract

BackgroundThe use of Bio 3D nerve conduits is a promising approach for peripheral nerve reconstruction. This study aimed to assess their safety in three patients with peripheral nerve defects in their hands.MethodsWe describe a single institution, non-blinded, non-randomised control trial conducted at Kyoto University Hospital. Eligibility criteria included severed peripheral nerve injuries or a defect in the region distal to the wrist joint not caused by a congenital anomaly; a defect with a length of ≤20 mm in a nerve with a diameter ≤2 mm; failed results of sensory functional tests; ability to register in the protocol within 6 months from the day of injury; refusal of artificial nerve or autologous nerve transplantation; age 20–60 years; and willingness to participate and provide informed written consent. Six weeks before transplantation, skin was harvested, dermal fibroblasts were isolated and expanded, and Bio 3D nerve conduits were created using a Bio 3D printer. Bio 3D nerve conduits were transplanted into the patients’ nerve defects. The safety of Bio 3D nerve conduits in patients with a peripheral nerve injury in the distal part of the wrist joint were assessed over a 48-week period after transplantation.ResultsNo adverse events related to the use of Bio 3D nerve conduits were observed in any patient, and all three patients completed the trial.ConclusionsBio 3D nerve conduits were successfully used for clinical nerve reconstruction without adverse events and are a possible treatment option for peripheral nerve injuries.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call