Abstract

A periodic analysis of a ventilated Trombe wall is presented. The analysis is able to take into account the storage effects and predict the daily or long term performance of the system. The thermal flux entering an air-conditioned space (maintained at 20°C) through the wall has been evaluated. Numerical calculations have been performed corresponding to the meteorological data on 19 January 1981 at New Delhi, a typical cold winter day. Subsequent parametric studies using the simulation indicated that the critical parameters were the mass flow rate of air, depth of plane of heat retrieval and the length of the network of pipe.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.