Abstract

Several imaging x-ray telescope (IXT) prototypes have been fabricated independently by the Institute of Precision Optical Engineering, which employed thermal slumping technology. To verify the performance of the IXT prototypes, a three-layer prototype with a focal length of 2052.5 mm was tested using a narrow beam at the Shanghai Synchrotron Radiation Facility. The performance testing posed a challenge due to the need to suppress the finite source distance effect on the IXT prototype (43-m long source-optic distance). In addition, limited use of motorized stages presents challenges. We present the experimental setups and detailed measurement approaches by utilizing limited measurement devices. The prototype is a segmented telescope comprising six sectors. For the best sector, the measured point spread function (PSF) yields a half power diameter (HPD) of 66″ and agrees well with modeling (62″) and the value measured at PANTER (65″). In addition, the integrated HPD of the whole prototype is 82″ obtained by coadding the PSFs of the six sectors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.