Abstract

Bovine serum albumin solutions at different temperature, pH, flow rate and operation pressure have been used as feed solution for studying performance of ultrafiltration membrane. Polysulfone membranes used for this experiment were in form of hollow fibers that have Molecular Weight Cut Off (MWCO) 60 kDa. Observation was focused on flux parameter and rejection coefficient towards protein during the process. Result shows that temperature, pH of BSA feed solution, flow rate and operation pressure can affect the flux and rejection coefficient of membrane. High temperature feed solution tend to decrease the flux but increase rejection coefficient. Rejection coefficient of membrane will increase while flux decreasing at pH of feed solution near to protein isoelectric point. High pressure of feed solution will increase flux but decrease rejection of membrane. Rejection of membrane will decrease and flux will increase when the process operated in slow flow rate. Keywords: Ultrafiltration Membrane, Bovine Serum Albumin, Feed solution, Flux, Rejection coefficient.