Abstract

This paper presents a performance prediction method for piezoelectric injection systems, based on finite element simulations. Two indexes representing the system performance are proposed: jetting velocity and droplet diameter. By combining Taguchi’s orthogonal array method and finite element simulation (FES), a finite element model of the droplet injection process, with different parameter combinations, was established. The two performance indexes, jetting velocity and droplet diameter, were accurately predicted, and their variation with time were investigated. Finally, the accuracy of the predicted results of the FES model was verified by experiments. The errors of the predicted jetting velocity and droplet diameter were 3.02% and 2.20%, respectively. It is verified that the proposed method has better reliability and robustness than the traditional method.