Abstract

We present results of a toy model study of performance of the Time-of-Flight detectors integrated into forward proton detectors. The goal of the ToF device is to suppress effects of additional soft processes (so called pile-up) accompanying the hard-scale central diffractive event, characterized by two tagged leading protons, one on each side from the interaction point. The method of mitigation of the pile-up effects exemplified in this study is based on measuring a difference between arrival times of these leading protons at the forward proton detectors and hence estimate the z-coordinate of the production vertex. We evaluate effects of the pile-up background by studying in detail its components, and estimate the performance of the ToF method as a function of the time and spatial resolution of the ToF device and of the number of pile-up interactions per bunch crossing. We also propose a new observable with a potential to efficiently separate central diffractive signal from the harsh pile-up environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.