Abstract
In this paper, we report on a systematic study of a soft X-ray Gas Electron Multiplier (GEM) detector built with aluminium-clad kapton GEM foils. The primary objective of this research is to comprehend the performance of this type of detector when irradiated with soft energy photons. The results are analysed and discussed with a particular focus on the long-term detector stability, as well as its gas gain and energy resolution uniformity across the detector area. Presented results lead us to the conclusion that the aluminium based GEM detector is a promising device to suppress the X-ray Fluorescence (XRF) background, simultaneously providing very good stability during long-term measurement campaigns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.