Abstract

In this paper, GT suite software is used to model the cooling system of military special vehicles with multiple power sources. The power drive system is composed of main engine, auxiliary engine and four hub motors. By constructing modular cooling unit, the volume of radiator and the layout of cooling unit are changed. While the total volume of radiator is unchanged, the cooling capacity of cooling system is improved. Firstly, the problem is simplified and modeled by high-temperature and low-temperature double circuit. The main engine with power of 600kW and auxiliary engine with power of 200kW are combined into a high-temperature circuit. The water temperature of the circuit is higher, about 90 ºC; Four hub motors with power of 440kw and their electrical components are combined into a low temperature circuit. The water temperature of this circuit is about 60 ºC. By modifying the volume, layout and number of radiators, the temperature of the dual circuit is analyzed, and it is found that when the total radiator volume remains the same, the cooling effect of the multi-radiator layout is better.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.