Abstract

The lowest temperature that can be achieved inStirling cycle cryocooler is governed by various losses. This paper presents performance prediction of Two Stage Stirling Cryocooler(for 20K as the second stage temperature) by using second order analysis which calculates the ideal refrigerating effect at intermediate and final stage temperatures and the ideal power input. The losses are found out for both the stages to determine the actual refrigerating effects and power input. The results obtained are in good agreement with reported values. The performance of the cryocooler is governed by various operating and geometric parameters. Parametric analysis is carried.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.