Abstract

In this paper, the performances of two adiabatic compressed air energy storage systems were determined. In system 1#, compressed air was reduced directly from 6.40 MPa to 2.50 MPa. In system 2#, compressed air was first reduced to 5.00 MPa and was later adjusted to 2.50 MPa by an ejector under an ejecting coefficient of 0.45. The mass flow of turbine 1# increased by 45%, and its power output capacity increased from 3.80 MW to 5.51 MW. The energy conversion efficiency of system 2# increased to 65.36% from 61.95% for system 1#. The application of the ejector improved the efficiency by 3.41%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.