Abstract

In this paper, a comprehensive computational fluid dynamics (CFD) modeling was built to reproduce the pool boiling in the evaporator section and the liquid film condensation in a closed thermosyphon. The two phase Volume Of Fluids (VOF) model was used to simulate the heat transfer during evaporation and condensation inside a closed thermosyphon. This CFD model was validated using experimental results, and a good agreement was observed. Moreover, the results were analyzed in terms of the vapor volume fraction variation, temperature and vertical velocity at different locations along the thermosyphon. A parametric study was also conducted to enhance the performance of the thermosyphon designed for solar thermal energy applications like domestic hot water systems. It is found that the performance of the two-phase closed thermosyphon can be improved by tilted fins integration on the lateral surface of the condenser section.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.