Abstract

The liquid nitrogen distribution at Variable Energy Cyclotron Centre, Kolkata, India K500 superconducting cyclotron uses parallel branches to cool the thermal shield of helium vessel housing the superconducting coil and the cryopanels. Liquid nitrogen is supplied to the thermal shields from a pressurised liquid nitrogen dewar. Direct measurement of flow is quite difficult and seldom used in an operational cryogenic system. The total flow and heat load of the liquid nitrogen system was estimated indirectly by continuous measurement of level in the liquid nitrogen tanks. A mathematical model was developed to evaluate liquid nitrogen flow in the parallel branches. The model was used to generate flow distribution for different settings and the total flow was compared with measured data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.