Abstract

The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI). To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms. PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479). Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI. The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality. A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays. Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies. The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI. National Taiwan University Hospital.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.