Abstract
Background: To investigate the feasibility of single reshaped Judkins left catheter for transradial coronary angiography. Methods: A total of 198 consecutive patients were enrolled in the first step study. Patients were randomly assigned to brachial type catheter group (BRACT group) or Judkins left catheter group (Judkins group). The inclusion criterion was the left coronary angiography which could be accomplished by either a brachial type catheter or a reshaped Judkins left catheter. The successful procedure was defined as both right and left coronary angiography could be completed with a single reshaped Judkins left catheter or a brachial type catheter. Furthermore, 1873 consecutive patients were continuously enrolled to observe the success rate of single Judkins left catheter for transradial coronary angiography. Results: Of the 198 patients, 191 were finally enrolled in this study according to the inclusion criteria, with 95 patients in BRACT group and96 inJudkins group. There were no significant differences on baseline between the two groups. Procedure success rate was 84.10% with a fluoroscopic exposure time of 3.81 ± 0.43 min in BRA-CT group, and 81.60% with a fluoroscopic exposure time of 4.05 ± 0.48 min in Judkins group (P > 0.05). No severe complications were found in either of the two groups. The success rates of 1869 patients with single Judkins left catheter for transradial coronary angiography were 75.33%. There were no complications in those patients. Conclusions: Transradial coronary angiography with a reshaped single Judkins left catheter is feasible and practical, with an accepted procedure success rate. This method should be worthy of further clinical validation in a larger scale population.
Highlights
Transradial coronary percutaneous procedures are associated with reduced entry site complications compared to transfemoral [1], and transradial procedures are becoming widely accepted by operators and patients because of the patients resuming activity immediately after the procedure and avoiding the discomfort of forced, prolonged bed rest
Of the 198 patients, 191 patients were eligible for the study, including patients in brachial type catheter (BRACT) group and in Judkins group
The patients in the Judkins group and BRACT group were well matched for age, sex, and other demographic data (Table 1)
Summary
Transradial coronary percutaneous procedures are associated with reduced entry site complications compared to transfemoral [1], and transradial procedures are becoming widely accepted by operators and patients because of the patients resuming activity immediately after the procedure and avoiding the discomfort of forced, prolonged bed rest. The purpose of this study was to evaluate the feasibility of single reshaped Judkins left catheter for engaging both coronary arteries via the right transradial artery approach, compared with conventional brachial type catheter BRACT. The successful procedure was defined as both right and left coronary angiography could be completed with a single reshaped Judkins left catheter or a brachial type catheter. 1873 consecutive patients were continuously enrolled to observe the success rate of single Judkins left catheter for transradial coronary angiography. Conclusions: Transradial coronary angiography with a reshaped single Judkins left catheter is feasible and practical, with an accepted procedure success rate. This method should be worthy of further clinical validation in a larger scale population
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.