Abstract

The paper presents observed damage in reinforced concrete buildings during the 27 February 2010 Maule earthquake in Chile. Performance of concrete frame and shear wall buildings are discussed with emphasis on seismic deficiencies in design and construction practices. It is shown that the majority of structural damage in multistorey and high-rise buildings can be attributed to poor performance of slender shear walls, without confined boundary elements, suffering from crushing of concrete and buckling of vertical wall reinforcement. Use of irregular buildings, lack of seismic detailing, and the interference of nonstructural elements were commonly observed seismic deficiencies. A comparison is made between Chilean and Canadian design practices with references made to the applicable code clauses. Lessons are drawn from the observed structural performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.