Abstract

The design of an effective storm water junction structure requires calculation of the energy losses, and associated backwater effects, in the vicinity of the junction under anticipated maximum flows in the incoming sewers. In the case of hydraulically inefficient junctions, energy losses due to stream mixing and from drag can lead to surcharged conditions in the conduits. Under these conditions Sangster suggests appropriate energy loss coefficients based on extensive tests on small-scale junction structures in which the inflow and outflow pipes were surcharged. However, efficient storm sewer systems normally operate under free surface conditions. Consequently the experimental program, described in this note, had the following main objectives: 1. To provide data on the relative efficiency of different-shaped junction structures operating under free surface conditions; 2. to investigate junctions having large inlet pipe diameters and small incoming pipe slopes; and 3. determination of suitable modifications to junction geometry in light of recent attempts to improve the performance of some inefficient junctions in an existing sewer system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.