Abstract
We present systematic studies of efficiency-rate characteristics of the MICROMEGAS detector in high-intensity hadron beams. The discharge probability has been studied as a function of the gain for several gas mixtures. Using a full tracking system of several MICROMEGAS chambers we measured simultaneously the gain, the efficiency, the spatial resolution and the sparking probability. We are discussing the various issues, with single and double amplification, for the use of this detector in future high-rate hadron accelerators.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.