Abstract

This study was performed of the heat transfer and the pressure drop in superconducting cable former of more realistic geometry. Liquid nitrogen passes through the former for cooling. Corrugated pipes are used as formers to ensure flexibility, and the ratio of pitch and depth of corrugation p/ e is less than 5, which is out of the range of normal usage. Range of the test was p/ e=1–15, e/ D=0.039–0.118. The heat transfer and the pressure drop were proportional to the corrugation depth, which is the same with the results reported by previous researchers. But the effect of pitch was different from the results of the range p/ e>10. The heat transfer and the pressure drop had the maximum values on the range of p/ e=5–10. Based on the numerical results, discussion was made on the design of superconducting cable former.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.