Abstract

An attempt is made to design, fabricate and test a miniature heat pipe with 5 mm diameter and 150 mm length with a thermal capacity of 10 W. Experiments were conducted with and without working fluid for different thermal loads to assess the performance of heat pipe. The working fluids chosen for the study were same as those commonly used namely, water, methanol and acetone. The temperature distribution across the heat pipe was measured and recorded using thermocouples. The performance of the heat pipe was quantified in terms of thermal resistance and overall heat transfer coefficient. The amount of liquid filled was varied and the variation of the performance parameters for varying liquid inventory is observed. Finally, optimum liquid fill ratio is identified in terms of lower temperature difference and thermal resistance and higher heat transfer coefficient. The data reported in this study will serve as a good database for the researchers in this field. Overall heat transfer coefficient of the Miniature heat pipe is found to be the maximum for the Acetone as working fluid.DOI: http://dx.doi.org/10.3329/jme.v41i2.7473

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.