Abstract
Fiber reinforced polymer (FRP) has become increasingly popular for the repair and retrofit of reinforced concrete structures. Surface condition of the substrate, in particular its flatness, plays a significant role on the performance of retrofitted structure. This paper reports on the effects of out-of-flatness as a surface defect on the flexural performance of FRP repair systems. The experimental program includes a total of nineteen specimens with two different FRP repair systems (wet lay-up and precured), and two different levels of surface unevenness in the form of peaks or valleys. Tests showed that the peaks on concrete surface, in the range studied, did not have a significant effect on the performance of FRP systems. However, valleys or depressions deeper than 1.6 mm over a length of 305 mm (1.38 × 10−4 mm−1 curvature) could reduce the strength of FRP systems. Typical failure mode was FRP debonding observed in both FRP repair systems. Test results and threshold recommendations were verified using a nonlinear finite element analysis. Bond-dependent coefficient for various surface flatness levels were analyzed and compared with the results available in the literature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.