Abstract
Research of perform of embedded precast beam was result many data (a) average tensile strength of joint between plate embedeed with plate joint was 628,55 Mpa (b)average tensile strength of joint between plate with reinforce bar D12,59 was 597,16 Mpa for tensile strength of plate with failure at reinforce bar (c) average tensile strength of reinforce bar D12,59 was 605,23 Mpa and yield strength was 425,87 Mpa (d)average tensile strength of plate 4,58 mm thick was 456,86 Mpa and yield strength was 335,02 Mpa. For welded joint need several control quality so that no hole in that perform of welded couse can decrease tensile strength of joint. Conclusion of this research is embedded for precast concrete type wet and dry can be used for construction of joints of beam.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Applied Research on Civil Engineering and Environment (ARCEE)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.