Abstract
Experimental investigations on model counterfort retaining walls have been carried out to study the lateral movement of the walls and the nature of the failure modes. Mild steel plates of size 1,000 × 900 × 8 mm were used as model retaining walls and were placed in a tank of size 900 × 900 × 670 mm. Ennore sand, obtained from Madras India, and Fly ash, obtained from Panki Thermal Power Plant, India were used as backfill material. Tests were carried out both with and without reinforced backfill. Two types of loading conditions were applied: (i) line load and (ii) uniform surcharge. The shape and size of the failure wedge was studied by observing displacement of bands of colored through a Perspex plate fixed on one side of the tank. Plots of overturning moment against the rotation of a wall top show that with the increase in rotation of wall, the overturning moment decreases. The minimum value of overturning moment is taken as the limiting value. The failure surfaces obtained in different cases are linear and parabolic in shape.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.