Abstract

This paper investigates the structural behaviour of two connected Sandwiched Precast Lightweight Foamed Concrete Panel (PLFP) in term of their load bearing capacities and failure modes. Three (3) connected PLFP panels were cast using foamed concrete as the wythe and polystyrene as the core layer. Each connected panel were cast from two single panels connected using L-bar connection. The panels were strengthened with steel bar reinforcement embedded in both wythes which were connected to each other by the steel shear truss connectors. The connected PLFP panels were tested under flexural load. A single PLFP panel was cast as a control panel and tested under axial load. The results were analysed in term of the panel’s ultimate load, crack pattern and mode of failure. Results showed that the two connected PLFP panels were able to sustain slightly lower ultimate load compared to single PLFP panel. Crack at 45 degree angle at top half of panel and small crack at surface between joint of the connection were observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.