Abstract
This paper discusses the electrical impedance behaviour, measured according to the Wenner’s method, of three different concrete mixes during accelerated degradation tests. Being a first attempt to move from laboratory to in-field applications targeted to long-term monitoring, the same electrode array configuration and set-up (AC current at 10 kHz) is used. Results show that electrical impedance decreases down to 24% in capillary water absorption tests, 77% and 86% in salt-spray chamber and wet/dry cycles with 3.5% NaCl solution, respectively. The two new low-clinker cements adopted seem to improve the measurement sensitivity towards contaminants ingress with respect to the commercial one (reference).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.