Abstract
This paper presents the results of an experimental study carried out within the National Institute for Research, Development in Constructions, Urbanism and Sustainable Territorial Development URBAN INCERC, on a system of walls made of ACC blocks, according to the standard SR EN 771-4 [8], having a density of 480 kg/m3 and standardized compressive strength of 3.5 N/mm2, using mortar type binder class M2.5 with compressive strength of 2.5 N/mm2. It was exposed to the action of standardized fire for a period of 220 minutes, after 10 days from the execution of the masonry. The results showed that, following the tests on the burned samples, extracted from the wall subject to the test, the standardized unit compressive strength decreased by 54%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.