Abstract

A prototype electromagnetic calorimeter containing 180 litres of liquid krypton has been tested in electron and muon beams at the CERN SPS. The main features of this detector are its active shower medium, a granularity of 2 cm with tower readout, and the use of the initial current readout technique with an effective shaping time of about 60 ns. An energy resolution for electrons of 4.1% √E[ GeV] with a constant term of 0.4% and a noise contribution of 50 MeV has been achieved. The calorimeter has a spatial resolution of 4.5 mm √E[ GeV] with a constant term of 0.3 mm and a time resolution of about 0.5 ns for energies larger than 10 GeV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.