Abstract
During the defrosting process, the temperature in the cabinet of a showcase becomes higher than the set point. This phenomenon is undesirable for foods or products stored. It is essential to develop an efficient defrosting method to prevent large temperature fluctuations. In the present study, the performance of the showcase refrigeration system with three evaporators was measured during on–off cycling and hot-gas bypass defrost. Based on the test results, the effects of off-period in the on–off cycling and EEV opening in the hot-gas bypass defrosting cycle on the performance of showcase system were analyzed. In addition, the operating characteristics of the hot-gas bypass defrosting cycle were compared with those of the on–off cycling. The hot-gas bypass defrosting method showed higher refrigerating capacity and less temperature fluctuations than the on–off cycling under frosting/defrosting conditions even though it required more compressor power.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.