Abstract

The experience gained in the operation of the present High Voltage system of the Tile calorimeter in the ATLAS detector and the new HL-LHC constraints, in particular the increase of the radiation, lead to the proposal of changing the currently embedded regulation system to be a remote system in the counting room, by adding easily new functionalities. The system described in this note is using the same regulation scheme as the current one and distributes the individual High Voltage settings with 100 m long multi-conductor cables. The tests show that it reaches the same good performance in terms of regulation stability and noise, while allowing a permanent access to the electronics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.