Abstract

Rapid development and climate change has endangered the availability of water resources worldwide. This study look into the potential of the applying a rainwater harvesting system (RWHS) for non- potable water usage in a doublestorey residential terrace house using Tangki NAHRIM 2.0 (TN2.0). TN2.0 is a web application that adopt the yield-after-spillage (YAS) convention to identify the optimum rainwater tank size. It is found that for a house of size 86.86 m<sup>2</sup>, the optimum tank size is 2 m<sup>3</sup> with water-saving and storage efficiency values of 51% and 63.2% respectively. Additionally, the performance of the optimum tank size of 2 m<sup>3</sup> was further examined under different water demand. It was found that a 2 m<sup>3</sup> tank was still able to save water up to 42.1% for a family of 10 persons. Meanwhile, the storage efficiency shows a little increment from 63.2% to 67.8%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.