Abstract
Forensic DNA casework samples are often of insufficient quantity or quality to generate full profiles by conventional DNA typing methods. Polymerase chain reaction (PCR) amplification of short tandem repeat (STR) loci is inherently limited in samples containing degraded DNA, as the cumulative size of repeat regions, primer binding regions, and flanking sequence is necessarily larger than the PCR template. Additionally, traditional capillary electrophoresis (CE) assay design further inherently limits shortening amplicons because the markers must be separated by size. Non-traditional markers, such as single nucleotide polymorphisms (SNPs) and insertion deletion polymorphisms (InDels), may yield more information from challenging samples due to their smaller amplicon size. In this study, the performance of a next generation sequencing (NGS) SNP assay and CE-based STR, mini-STR, and InDel assays was evaluated with a series of fragmented, size-selected samples. Information obtained from the NGS SNP assay exhibited higher overall inverse random match probability (1/RMP) values compared to the CE-based typing assays, with particular benefit for fragment sizes ≤150 base pairs (bp). The InDel, mini-STR, and NGS SNP assays all had similar percentages of loci with reportable alleles at this level of degradation; however, the relatively fewer number of loci in the InDel and mini-STR assays results in the NGS SNP assay having at least nine orders of magnitude higher 1/RMP values. In addition, the NGS SNP assay and three CE-based assays (two STR and one InDel assay) were tested using a dilution series consisting of 0.5ng, 0.1ng, and 0.05ng non-degraded DNA. All tested assays showed similar percentages of loci with reportable alleles at these levels of input DNA; however, due to the larger number of loci, the NGS SNP assay and the larger of the two tested CE-based STR assays both resulted in considerably higher 1/RMP values than the other assays. These results indicate the potential advantage of NGS SNP assays for forensic analysis of degraded DNA samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.